Features:
High-Class Grating and Hermetic Light Path Design: Ensures ultra-low stray light, providing accurate and precise measurements by minimizing light interference.
SiO₂ Coating Optical Mirror: Effectively reduces external pollution, maintaining the performance and accuracy of the instrument by protecting against contamination.
Real-Time Lamp Lifetime Monitoring: Continuously monitors the lifespan of Deuterium and Tungsten lamps, alerting users when a replacement is needed to ensure consistent performance.
Automatic Wavelength Calibration and Dark Current Calibration: Automatically calibrates wavelength settings, changes the lamp source, and adjusts for dark current, ensuring accurate and reliable results.
GLP Self-Check Function: Performs self-checks on wavelength and photometry accuracy, ensuring compliance with Good Laboratory Practice (GLP) and maintaining measurement consistency.
Comprehensive analysis capabilities: supports photometry, quantitative analysis, kinetics, multi-wavelength testing (up to 8), scanning (190-1100nm), and DNA/protein analysis with curve storage.
Parameters
Model |
BK-UV1900 BK-UV1900PC |
BK-V1900 BK-V1900PC |
|
Optical System |
Single Beam, Grating 1200 lines/mm |
||
Wavelength Range |
190~1100nm |
320~1100nm |
|
Spectral Bandwidth |
2nm |
||
Wavelength Accuracy |
± 0.5nm |
||
Wavelength Repeatability |
≤ 0.3nm |
||
Photometric Accuracy |
± 0.002A (0~0.5Abs), ± 0.004A (0.5~1.0Abs), ± 0.5% T (0~100% T) |
||
Photometric Repeatability |
0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤ 0.2% T (0~100% T) |
||
Stray Light |
≤ 0.04% T @ 360nm; 220nm |
||
Stability |
± 0.001A / h @ 500nm |
||
Baseline Flatness |
± 0.002A |
||
Noise |
0.0005Abs @ 500nm |
||
Display |
480 *272 65 thousand true color TFT LCD |
||
Photometric Mode |
T, A, C, E |
||
Photometric Range |
0~200% T,-0.301~3.0A |
||
Detector |
Silicon Photodiode |
||
Light Source |
Deuterium Lamp, Tungsten Lamp |
||
Input |
Membrane Keypad |
||
Output |
USB2.0*2 Print and data output USB1.0 Connect PC |
||
Standard Accessories |
10mm glass cuvette *4 units 10mm quartz cuvette *2 units |
10mm glass uvette *4 units |
|
Optional Accessories |
Single cell holder,General cell holder,Test tube holder,Solid sample holder,Deuterium lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketedcell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system |
||
Power Supply |
AC110V/220±10% ,60/50Hz |
||
Packing Size(mm) |
620*500*370 |
620*500*370 |
|
Gross Weight(kg) |
18 |
16.5 |