Features:
Resistivity of deionized water: 16-18.2MΩ.cm
Flow rate: up to 2 liters/minute (with pressure tank), which can satisfy your basic experimental water consumption.
LCD controlling system and real-time feedback: the LCD controlling system serves as the user interface, providing real-time feedback on system performance, water quality, and operational status.
3-Way water quality sensors, multi-point monitoring: these sensors in the deionized water system monitor water quality at different points in the water treatment process to ensure the water produced meets the required purity standards.
Timing and quality dispensing: this ensure that the water is dispensed at right time and quality and can regulate flow.
Producing single stage RO water and deionized water: you can get RO water and deionized water in a device, which can save your cost and improve efficiency.
Flow Schematic
Specification
Model |
Master-Q15 |
Master-Q15UT |
Master-Q30 |
Master-Q30UT |
Output(25°C)* |
15 liters/hour |
30 liters/hour |
||
Flow rate |
Up to 2 liters/minute(with pressure tank) |
|||
Pure water outlet |
2: reverse osmosis water, deionized water |
|||
Deionized water quality |
||||
Resistivity |
16-18.2MΩ.cm |
|||
Bacteria |
N/A |
<0.01cfu/ml |
N/A |
<0.01cfu/ml |
Particle(>0.1μm) |
N/A |
<1/ml |
N/A |
<1/ml |
RO water quality |
||||
Ion rejection rate |
97%-99% (new RO membrane) |
|||
Organic rejection rate |
>99%, when MW>200 Dalton |
|||
Particles and bacteria rejection rate |
>99% |
|||
Feed water requirements |
Tap water, temperature:5-45°C,pressure:1.0-4.0Kgf/cm2 |
|||
Dimension and weight |
Length×Width×Height:500×360×540mm / Weight: about 20Kg |
|||
Electrical requirements |
AC100-240V, 50/60Hz |
|||
Power |
120W |
|||
Standard configuration |
Main body (Including 1 set of cartridge)+15 liters pressure tank |
Cartridges
Item no. |
Commodity |
Approximate replacement term /set |
|
PC-M-PP |
5µm spun fiber cartridge |
2-6 months |
|
PC-M-KDF |
KDF+ granular active carbon mixed cartridge |
12 months |
|
PC-M-AC-G |
Granular active carbon cartridge |
6 months |
|
RO-100GPD |
100 GPD reverse osmosis membrane |
12-24 months |
|
RO-200GPD |
200 GPD reverse osmosis membrane |
12-24 months |
|
PTC-AC-HZB1 |
Reducing TOC cartridge |
9000 liters pure water |
|
PTC-MBR-M |
Mixed bed resin cartridge |
1000 liters pure water |
|
PTC-MBR-M4 |
4-in-I mixed bed resin cartridge module |
4000 liters pure water |
|
PTC-UPPR-M |
Ultrapure polishing resin cartridge |
1000 liters pure water |
|
PTC-UPPR-M4 |
4-in-1 ultrapure polishing resin cartridge |
4000 liters pure water |
|
TF-(0.45+0.1)µm-S |
(0.45+0.1)µm terminal filter |
- |
|
UF-5000D |
MWCO5000D UF cartridge |
- |
|
LAMP-(185nm&254nm)-10W-M |
Double wavelength(185&254)nm uv lamp |
9000 hours |
|
LAMP-254-10W-M |
254 nm wavelength uv lamp |
9000 hours |