Mini Centrifuge
Mini Centrifuge
12000
0.2mL, 0.5mL, 1.5mL, 2mL
8550×g
Yes
packed with 2 rotors,8*2ml/1.5ml/0.5ml/0.2ml and 0.2ml*8*4(PCR)
Availability: | |
---|---|
Quantity: | |
Mini-4G/ Mini-7G /Mini-10G/Mini-12G Mini Micro Centrifuge
Features:
1. Mini-4G/Mini-7G/Mini-10G/Mini-12G centrifuge is widely used in laboratory and hospital.
2. This model can fit in 2ml, 1.5ml, 0.5ml and 0.2ml tubes.
3. The handheld centrifuge is very suitable for microtubule filtration and fast centrifugation, the micro blood cell separation, microbial sample processing, experimental partition centrifugal of PCR.
4. Light weight, small size and beautiful design.
5. Easily control, super speed protection.
Product Models and Main Technical Parameters
Models | Mini-4G | Mini-7G | Mini-10G | Mini-12G |
ElectricSource Input | AC85-264V/50/60Hz | AC85-264V/50/60Hz | AC85-264V/50/60Hz | AC85-264V/50/60Hz |
Rate of Work Input | 12W | 18W | 25W | 30W |
Motor | DC24V | DC24V | DC24V | DC24V |
Control | PI/Power direct drive | |||
Fuse | PPTC/self recovery fuse/No replacement needed | |||
Rotor Capacity | 2/1.5/0.5/0.2ml×80.2ml×8×4(PCR) | 2/1.5/0.5/0.2ml×80.2ml×8×4(PCR) | 2/1.5/0.5/0.2ml×80.2ml×8×4(PCR) | 2/1.5/0.5/0.2ml×80.2ml×8×4(PCR) |
maximum speed[r/min.] | 4,000r/min.±3% | 7,000r/min.±3% | 10,000r/min.±3% | 12,000r/min.±5% |
The maximum relative centrifugal force[×g] | 990×g | 2,910×g | 5,610×g | 8,550×g |
Size[mm]: LengthXWidthXHeight | 158×172×123mm | 158×172×123mm | 158×172×123mm | 158×172×123m |
The noise at highest speed | ≤42dB(A) | ≤43dB(A) | ≤45dB(A) | ≤47dB(A) |
Note: Ambient temperature 23 ° C / at 23 ° C ambient temperature
Rotor photos:
Each mini centrifuge will be packed with 2 kinds of rotors and 1 adapter of 0.5ml and 1 adapter of 0.2ml.
1st Rotor:
2nd Rotor:
0.5ml Adapters:
0.2ml Adapters:
Mini-4G/ Mini-7G /Mini-10G/Mini-12G Mini Micro Centrifuge
Features:
1. Mini-4G/Mini-7G/Mini-10G/Mini-12G centrifuge is widely used in laboratory and hospital.
2. This model can fit in 2ml, 1.5ml, 0.5ml and 0.2ml tubes.
3. The handheld centrifuge is very suitable for microtubule filtration and fast centrifugation, the micro blood cell separation, microbial sample processing, experimental partition centrifugal of PCR.
4. Light weight, small size and beautiful design.
5. Easily control, super speed protection.
Product Models and Main Technical Parameters
Models | Mini-4G | Mini-7G | Mini-10G | Mini-12G |
ElectricSource Input | AC85-264V/50/60Hz | AC85-264V/50/60Hz | AC85-264V/50/60Hz | AC85-264V/50/60Hz |
Rate of Work Input | 12W | 18W | 25W | 30W |
Motor | DC24V | DC24V | DC24V | DC24V |
Control | PI/Power direct drive | |||
Fuse | PPTC/self recovery fuse/No replacement needed | |||
Rotor Capacity | 2/1.5/0.5/0.2ml×80.2ml×8×4(PCR) | 2/1.5/0.5/0.2ml×80.2ml×8×4(PCR) | 2/1.5/0.5/0.2ml×80.2ml×8×4(PCR) | 2/1.5/0.5/0.2ml×80.2ml×8×4(PCR) |
maximum speed[r/min.] | 4,000r/min.±3% | 7,000r/min.±3% | 10,000r/min.±3% | 12,000r/min.±5% |
The maximum relative centrifugal force[×g] | 990×g | 2,910×g | 5,610×g | 8,550×g |
Size[mm]: LengthXWidthXHeight | 158×172×123mm | 158×172×123mm | 158×172×123mm | 158×172×123m |
The noise at highest speed | ≤42dB(A) | ≤43dB(A) | ≤45dB(A) | ≤47dB(A) |
Note: Ambient temperature 23 ° C / at 23 ° C ambient temperature
Rotor photos:
Each mini centrifuge will be packed with 2 kinds of rotors and 1 adapter of 0.5ml and 1 adapter of 0.2ml.
1st Rotor:
2nd Rotor:
0.5ml Adapters:
0.2ml Adapters: