YT5
5000
5mL, 7mL, 10mL, 15mL, 50mL, 100mL, 250mL, PCR/ELISA Plate
4730×g
No
4×250ml
Availability: | |
---|---|
Quantity: | |
YT5 5000rpm, 4*250ml, Pre-cooling Design, Bench Top Universal Centrifuge, Smaller Size, Support Swing/Microplate/Fixed Rotor
Features:
* Refrigerated centrifuge, widely used in laboratory, blood bank and hospital.
* Imbalance sensor and over temperature sense
* Pre-cooling design, 10 kinds of acceleration and deceleration
* More than 20 kinds of rotors for your choice
* Low noise, small vibration and compact design.
* Import compressors fluorine free, double cycle cooling, free environment pollution
* The centrifuge body is made of high-quality steel, very safe
* User-friendly large digital display provides speed, time and temperature parameters
* Brushless motor which in great torque, no powder pollution, free maintenance, quick in speed up and down
YT5 Technical Parameter
Max. Speed | 5000rpm |
Max. RCF | 4730×g |
Max. Capacity | 4×250ml |
Time Range | 0~9h59min |
RPM/RCF Convert | Yes |
Noise (dB) | ≤ 58 |
Temperature | -20℃-40℃ |
Acc/Dec | 10 Kinds |
Speed Accuracy | ±20r/min |
Temperature Accuracy | ±1℃ |
Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
Size (W x D x Hmm) | 650×665×400mm |
Net Weight(Kg) | 83KG |
Certificates | CE,ISO & Calibration report are available |
YT5R Technical Parameter
Max. Speed | 5000rpm |
Max. RCF | 4730×g |
Max. Capacity | 4×250ml |
Time Range | 0~99min |
RPM/RCF Convert | Yes |
Noise (dB) | ≤ 58 |
Temperature | / |
Acc/Dec | 10 Kinds |
Speed Accuracy | ±20r/min |
Temperature Accuracy | / |
Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
Size (W x D x Hmm) | 400×570×320mm |
Net Weight(Kg) | 35KG |
Certificates | CE,ISO & Calibration report are available |
Matched Rotors for YT5/YT5R
Order No | Rotor | Max Speed(r/min) | Volume(ml) | Max RCF(×g) |
D5-1 | Swing rotor(round cup) | 4000 | 4×250ml | 2880 |
D5-2 | Swing buckets | 4000 | 4×16×7ml | 2860 |
D5-3 | 4000 | 4×16×5ml | 2470 | |
D5-4 | 4000 | 4×13×10ml | 2830 | |
D5-5 | Swing rotor | 5000 | 4×1×50ml | 4730 |
D5-6 | 4×1×100ml | 4730 | ||
D5-7 | 4000 | 4×2×100ml | 3020 | |
D5-8 | 4×2×50ml | 3020 | ||
D5-9 | 4×4×15ml | 3020 | ||
D5-10 | 4×6×15ml | 3020 | ||
D5-11 | 4×4×10/7 | 2770 | ||
D5-12 | 4×4×5 vacuum tube adapters | 2360 | ||
D5-13 | 4×6×10/7 | 2770 | ||
D5-14 | 4×6×5 vacuum tube adapters | 2360 | ||
D5-15 | 4×8×10/7 | 2770 | ||
D5-16 | 4×8×5 vacuum tube adapters | 2360 | ||
D5-17 | 4×12×5 vacuum tube | 2480 | ||
D5-18 | 4×12×7 vacuum tube | 2760 | ||
D5-19 | 4×10×10 vacuum tube | 2880 | ||
D5-20 | Microplate rotor | 4000 | 2×3×96 well | 2310 |
D5-21 | Fixed rotor | 5000 | 6×15ml | 2540 |
D5-22 | Fixed rotor | 5000 | 12×15ml | 3080 |
D5-23 | 5000 | 24×15ml | 3500 | |
D5-24 | 5000 | 30×15ml | 3830 | |
D5-25 | 5000 | 4×50ml | 2520 | |
D5-26 | 5000 | 6×50ml | 2850 | |
D5-27 | 5000 | 12×50ml | 3860 | |
D5-28 | 5000 | 4×100ml | 2630 | |
D5-29 | 5000 | 6×100ml | 3130 |
YT5 5000rpm, 4*250ml, Pre-cooling Design, Bench Top Universal Centrifuge, Smaller Size, Support Swing/Microplate/Fixed Rotor
Features:
* Refrigerated centrifuge, widely used in laboratory, blood bank and hospital.
* Imbalance sensor and over temperature sense
* Pre-cooling design, 10 kinds of acceleration and deceleration
* More than 20 kinds of rotors for your choice
* Low noise, small vibration and compact design.
* Import compressors fluorine free, double cycle cooling, free environment pollution
* The centrifuge body is made of high-quality steel, very safe
* User-friendly large digital display provides speed, time and temperature parameters
* Brushless motor which in great torque, no powder pollution, free maintenance, quick in speed up and down
YT5 Technical Parameter
Max. Speed | 5000rpm |
Max. RCF | 4730×g |
Max. Capacity | 4×250ml |
Time Range | 0~9h59min |
RPM/RCF Convert | Yes |
Noise (dB) | ≤ 58 |
Temperature | -20℃-40℃ |
Acc/Dec | 10 Kinds |
Speed Accuracy | ±20r/min |
Temperature Accuracy | ±1℃ |
Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
Size (W x D x Hmm) | 650×665×400mm |
Net Weight(Kg) | 83KG |
Certificates | CE,ISO & Calibration report are available |
YT5R Technical Parameter
Max. Speed | 5000rpm |
Max. RCF | 4730×g |
Max. Capacity | 4×250ml |
Time Range | 0~99min |
RPM/RCF Convert | Yes |
Noise (dB) | ≤ 58 |
Temperature | / |
Acc/Dec | 10 Kinds |
Speed Accuracy | ±20r/min |
Temperature Accuracy | / |
Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
Size (W x D x Hmm) | 400×570×320mm |
Net Weight(Kg) | 35KG |
Certificates | CE,ISO & Calibration report are available |
Matched Rotors for YT5/YT5R
Order No | Rotor | Max Speed(r/min) | Volume(ml) | Max RCF(×g) |
D5-1 | Swing rotor(round cup) | 4000 | 4×250ml | 2880 |
D5-2 | Swing buckets | 4000 | 4×16×7ml | 2860 |
D5-3 | 4000 | 4×16×5ml | 2470 | |
D5-4 | 4000 | 4×13×10ml | 2830 | |
D5-5 | Swing rotor | 5000 | 4×1×50ml | 4730 |
D5-6 | 4×1×100ml | 4730 | ||
D5-7 | 4000 | 4×2×100ml | 3020 | |
D5-8 | 4×2×50ml | 3020 | ||
D5-9 | 4×4×15ml | 3020 | ||
D5-10 | 4×6×15ml | 3020 | ||
D5-11 | 4×4×10/7 | 2770 | ||
D5-12 | 4×4×5 vacuum tube adapters | 2360 | ||
D5-13 | 4×6×10/7 | 2770 | ||
D5-14 | 4×6×5 vacuum tube adapters | 2360 | ||
D5-15 | 4×8×10/7 | 2770 | ||
D5-16 | 4×8×5 vacuum tube adapters | 2360 | ||
D5-17 | 4×12×5 vacuum tube | 2480 | ||
D5-18 | 4×12×7 vacuum tube | 2760 | ||
D5-19 | 4×10×10 vacuum tube | 2880 | ||
D5-20 | Microplate rotor | 4000 | 2×3×96 well | 2310 |
D5-21 | Fixed rotor | 5000 | 6×15ml | 2540 |
D5-22 | Fixed rotor | 5000 | 12×15ml | 3080 |
D5-23 | 5000 | 24×15ml | 3500 | |
D5-24 | 5000 | 30×15ml | 3830 | |
D5-25 | 5000 | 4×50ml | 2520 | |
D5-26 | 5000 | 6×50ml | 2850 | |
D5-27 | 5000 | 12×50ml | 3860 | |
D5-28 | 5000 | 4×100ml | 2630 | |
D5-29 | 5000 | 6×100ml | 3130 |