YT20
21000
0.5mL, 1.5mL, 2mL, 5mL, 7mL, 10mL, 15mL, 20mL, 30mL, 50mL, 70mL, 85mL, 100mL, PCR/ELISA Plate
30910×g
Yes
6×100ml
Availability: | |
---|---|
Quantity: | |
YT20 21000rpm with 1.5/2ml, 5ml.10ml,15ml,30ml,50ml, 85ml, 100ml Rotors
Features:
* Brush-less frequency motor with simpler construction, more reliable performance, longer life and quietly running
* Automatically electric lid lock, super speed, over temperature protection and imbalance protection. The centrifuge body is made of high quality steel, safe and reliable.
* Rotor is connected to spindle by specialized taper sleeve, loading simple and quick, no direction, safe and reliable.
* Microprocessor control.
* Digital display in time, speed and RCF.
* 10 kinds of program stored in the memory, 10 kinds of accelerating and decelerating speed for your choice.
* 3 tiers protection steel cover, stainless steel chamber, safe and reliable.
YT20 Technical Parameter
Max. Speed | 21000rpm |
Max. RCF | 30910×g |
Max. Capacity | 6×100ml |
Time Range | 0~99min |
Noise (dB) | ≤60 |
Speed Accuracy | ±20r/min |
Voltage(V/Hz) | AC 220V/110V 50HZ 10A |
Size (W x D x Hmm) | 513×370×320mm |
Net Weight(Kg) | 42KG |
YT20R Technical Parameter
Max. Speed | 21000rpm |
Max. RCF | 30910×g |
Max. Capacity | 6×100ml |
Time Range | 1~9h59min |
Noise (dB) | ≤58dBA |
Temperature Range | -20~40℃ |
Speed Accuracy | ±20r/min |
Temperature Accuracy | ±1℃ |
Power Supply | AC 220V/110V 50HZ 10A |
Size (L x W x Hmm) | 570×620×380mm |
Net Weight(Kg) | 84KG |
Matched Rotors for YT20/YT20R
Order no | Rotor | Max Speed(r/min) | Volume(ml) | Max RCF(*g) |
TG20-1 | Fixed Rotor | 16000 | 4×8PCR | 15760 |
TG20-2 | Fixed Rotor | 15000 | 6×8PCR | 21420 |
TG20-3 | Fixed Rotor | 16000 | 8×8PCR | 17480 |
TG20-4 | Fixed Rotor | 15000 | 12×8PCR | 22930 |
TG20-5 | Fixed Rotor | 21000 | 12×1.5/2ml | 30910 |
TG20-6 | Fixed Rotor | 15000 | 40×0.5ml | 22920 |
TG20-7 | Fixed Rotor | 17000 | 24×1.5/2ml | 26460 |
TG20-8 | Fixed Rotor | 13500 | 30×1.5/2ml | 19340 |
TG20-9 | Fixed Rotor | 13000 | 48×1.5/2ml | 17930 |
TG20-10 | Fixed Rotor | 16000 | 16×5ml | 22020 |
TG20-11 | Fixed Rotor | 16000 | 6×10ml | 21500 |
TG20-12 | Fixed Rotor | 15000 | 12×10ml | 22680 |
TG20-13 | Fixed Rotor | 16000 | 12×7ml | 21380 |
TG20-14 | Fixed Rotor | 13000 | 16×10ml | 19490 |
TG20-15 | Fixed Rotor | 10000 | 12×15ml | 11840 |
TG20-16 | Fixed Rotor | 13000 | 8×15ml(conical) | 17790 |
TG20-17 | Fixed Rotor | 5000 | 24×15ml | 3500 |
TG20-18 | Fixed Rotor | 15000 | 8×20ml | 22680 |
TG20-19 | Fixed Rotor | 5000 | 30×15ml | 3830 |
TG20-20 | Fixed Rotor | 14000 | 6×30ml | 19060 |
TG20-21 | Fixed Rotor | 13000 | 6×50ml(conical) | 18840 |
TG20-22 | Fixed Rotor | 13000 | 6×50ml(round) | 18730 |
TG20-23 | Fixed Rotor | 13000 | 4×85ml | 18940 |
TG20-24 | Fixed Rotor | 12000 | 6×70ml | 15570 |
TG20-25 | Fixed Rotor | 12000 | 4×100ml | 14850 |
TG20-26 | Fixed Rotor | 10000 | 6×100ml | 11380 |
TG20-27 | Fixed Rotor | 18000 | 30×0.5ml | 26660 |
TG20-28 | Swing Rotor | 13000 | 4×5ml | 14960 |
TG20-29 | Vertical Rotor | 16000 | 16×5ml | 16540 |
TG20-30 | Vertical Rotor | 14000 | 8×30ml | 16450 |
TG20-31 | Microplate Rotor | 4000 | 2×3×48(well) | 2300 |
YT20 21000rpm with 1.5/2ml, 5ml.10ml,15ml,30ml,50ml, 85ml, 100ml Rotors
Features:
* Brush-less frequency motor with simpler construction, more reliable performance, longer life and quietly running
* Automatically electric lid lock, super speed, over temperature protection and imbalance protection. The centrifuge body is made of high quality steel, safe and reliable.
* Rotor is connected to spindle by specialized taper sleeve, loading simple and quick, no direction, safe and reliable.
* Microprocessor control.
* Digital display in time, speed and RCF.
* 10 kinds of program stored in the memory, 10 kinds of accelerating and decelerating speed for your choice.
* 3 tiers protection steel cover, stainless steel chamber, safe and reliable.
YT20 Technical Parameter
Max. Speed | 21000rpm |
Max. RCF | 30910×g |
Max. Capacity | 6×100ml |
Time Range | 0~99min |
Noise (dB) | ≤60 |
Speed Accuracy | ±20r/min |
Voltage(V/Hz) | AC 220V/110V 50HZ 10A |
Size (W x D x Hmm) | 513×370×320mm |
Net Weight(Kg) | 42KG |
YT20R Technical Parameter
Max. Speed | 21000rpm |
Max. RCF | 30910×g |
Max. Capacity | 6×100ml |
Time Range | 1~9h59min |
Noise (dB) | ≤58dBA |
Temperature Range | -20~40℃ |
Speed Accuracy | ±20r/min |
Temperature Accuracy | ±1℃ |
Power Supply | AC 220V/110V 50HZ 10A |
Size (L x W x Hmm) | 570×620×380mm |
Net Weight(Kg) | 84KG |
Matched Rotors for YT20/YT20R
Order no | Rotor | Max Speed(r/min) | Volume(ml) | Max RCF(*g) |
TG20-1 | Fixed Rotor | 16000 | 4×8PCR | 15760 |
TG20-2 | Fixed Rotor | 15000 | 6×8PCR | 21420 |
TG20-3 | Fixed Rotor | 16000 | 8×8PCR | 17480 |
TG20-4 | Fixed Rotor | 15000 | 12×8PCR | 22930 |
TG20-5 | Fixed Rotor | 21000 | 12×1.5/2ml | 30910 |
TG20-6 | Fixed Rotor | 15000 | 40×0.5ml | 22920 |
TG20-7 | Fixed Rotor | 17000 | 24×1.5/2ml | 26460 |
TG20-8 | Fixed Rotor | 13500 | 30×1.5/2ml | 19340 |
TG20-9 | Fixed Rotor | 13000 | 48×1.5/2ml | 17930 |
TG20-10 | Fixed Rotor | 16000 | 16×5ml | 22020 |
TG20-11 | Fixed Rotor | 16000 | 6×10ml | 21500 |
TG20-12 | Fixed Rotor | 15000 | 12×10ml | 22680 |
TG20-13 | Fixed Rotor | 16000 | 12×7ml | 21380 |
TG20-14 | Fixed Rotor | 13000 | 16×10ml | 19490 |
TG20-15 | Fixed Rotor | 10000 | 12×15ml | 11840 |
TG20-16 | Fixed Rotor | 13000 | 8×15ml(conical) | 17790 |
TG20-17 | Fixed Rotor | 5000 | 24×15ml | 3500 |
TG20-18 | Fixed Rotor | 15000 | 8×20ml | 22680 |
TG20-19 | Fixed Rotor | 5000 | 30×15ml | 3830 |
TG20-20 | Fixed Rotor | 14000 | 6×30ml | 19060 |
TG20-21 | Fixed Rotor | 13000 | 6×50ml(conical) | 18840 |
TG20-22 | Fixed Rotor | 13000 | 6×50ml(round) | 18730 |
TG20-23 | Fixed Rotor | 13000 | 4×85ml | 18940 |
TG20-24 | Fixed Rotor | 12000 | 6×70ml | 15570 |
TG20-25 | Fixed Rotor | 12000 | 4×100ml | 14850 |
TG20-26 | Fixed Rotor | 10000 | 6×100ml | 11380 |
TG20-27 | Fixed Rotor | 18000 | 30×0.5ml | 26660 |
TG20-28 | Swing Rotor | 13000 | 4×5ml | 14960 |
TG20-29 | Vertical Rotor | 16000 | 16×5ml | 16540 |
TG20-30 | Vertical Rotor | 14000 | 8×30ml | 16450 |
TG20-31 | Microplate Rotor | 4000 | 2×3×48(well) | 2300 |