Availability: | |
---|---|
Quantity: | |
Features:
High-Class Grating and Hermetic Light Path Design: Ensures ultra-low stray light, providing accurate and precise measurements by minimizing light interference.
SiO₂ Coating Optical Mirror: Effectively reduces external pollution, maintaining the performance and accuracy of the instrument by protecting against contamination.
Real-Time Lamp Lifetime Monitoring: Continuously monitors the lifespan of Deuterium and Tungsten lamps, alerting users when a replacement is needed to ensure consistent performance.
Automatic Wavelength Calibration and Dark Current Calibration: Automatically calibrates wavelength settings, changes the lamp source, and adjusts for dark current, ensuring accurate and reliable results.
GLP Self-Check Function: Performs self-checks on wavelength and photometry accuracy, ensuring compliance with Good Laboratory Practice (GLP) and maintaining measurement consistency.
Comprehensive analysis capabilities: supports photometry, quantitative analysis, kinetics, multi-wavelength testing (up to 8), scanning (190-1100nm), and DNA/protein analysis with curve storage.
Parameters
Model | BK-UV1900 BK-UV1900PC | BK-V1900 BK-V1900PC | |
Optical System | Single Beam, Grating 1200 lines/mm | ||
Wavelength Range | 190~1100nm | 320~1100nm | |
Spectral Bandwidth | 2nm | ||
Wavelength Accuracy | ± 0.5nm | ||
Wavelength Repeatability | ≤ 0.3nm | ||
Photometric Accuracy | ± 0.002A (0~0.5Abs), ± 0.004A (0.5~1.0Abs), ± 0.5% T (0~100% T) | ||
Photometric Repeatability | 0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤ 0.2% T (0~100% T) | ||
Stray Light | ≤ 0.04% T @ 360nm; 220nm | ||
Stability | ± 0.001A / h @ 500nm | ||
Baseline Flatness | ± 0.002A | ||
Noise | 0.0005Abs @ 500nm | ||
Display | 480 *272 65 thousand true color TFT LCD | ||
Photometric Mode | T, A, C, E | ||
Photometric Range | 0~200% T,-0.301~3.0A | ||
Detector | Silicon Photodiode | ||
Light Source | Deuterium Lamp, Tungsten Lamp | ||
Input | Membrane Keypad | ||
Output | USB2.0*2 Print and data output USB1.0 Connect PC | ||
Standard Accessories | 10mm glass cuvette *4 units 10mm quartz cuvette *2 units | 10mm glass uvette *4 units | |
Optional Accessories | Single cell holder,General cell holder,Test tube holder,Solid sample holder,Deuterium lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketedcell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system | ||
Power Supply | AC110V/220±10% ,60/50Hz | ||
Packing Size(mm) | 620*500*370 | 620*500*370 | |
Gross Weight(kg) | 18 | 16.5 |
Features:
High-Class Grating and Hermetic Light Path Design: Ensures ultra-low stray light, providing accurate and precise measurements by minimizing light interference.
SiO₂ Coating Optical Mirror: Effectively reduces external pollution, maintaining the performance and accuracy of the instrument by protecting against contamination.
Real-Time Lamp Lifetime Monitoring: Continuously monitors the lifespan of Deuterium and Tungsten lamps, alerting users when a replacement is needed to ensure consistent performance.
Automatic Wavelength Calibration and Dark Current Calibration: Automatically calibrates wavelength settings, changes the lamp source, and adjusts for dark current, ensuring accurate and reliable results.
GLP Self-Check Function: Performs self-checks on wavelength and photometry accuracy, ensuring compliance with Good Laboratory Practice (GLP) and maintaining measurement consistency.
Comprehensive analysis capabilities: supports photometry, quantitative analysis, kinetics, multi-wavelength testing (up to 8), scanning (190-1100nm), and DNA/protein analysis with curve storage.
Parameters
Model | BK-UV1900 BK-UV1900PC | BK-V1900 BK-V1900PC | |
Optical System | Single Beam, Grating 1200 lines/mm | ||
Wavelength Range | 190~1100nm | 320~1100nm | |
Spectral Bandwidth | 2nm | ||
Wavelength Accuracy | ± 0.5nm | ||
Wavelength Repeatability | ≤ 0.3nm | ||
Photometric Accuracy | ± 0.002A (0~0.5Abs), ± 0.004A (0.5~1.0Abs), ± 0.5% T (0~100% T) | ||
Photometric Repeatability | 0.001Abs (0~0.5Abs), 0.002Abs (0.5~1.0Abs), ≤ 0.2% T (0~100% T) | ||
Stray Light | ≤ 0.04% T @ 360nm; 220nm | ||
Stability | ± 0.001A / h @ 500nm | ||
Baseline Flatness | ± 0.002A | ||
Noise | 0.0005Abs @ 500nm | ||
Display | 480 *272 65 thousand true color TFT LCD | ||
Photometric Mode | T, A, C, E | ||
Photometric Range | 0~200% T,-0.301~3.0A | ||
Detector | Silicon Photodiode | ||
Light Source | Deuterium Lamp, Tungsten Lamp | ||
Input | Membrane Keypad | ||
Output | USB2.0*2 Print and data output USB1.0 Connect PC | ||
Standard Accessories | 10mm glass cuvette *4 units 10mm quartz cuvette *2 units | 10mm glass uvette *4 units | |
Optional Accessories | Single cell holder,General cell holder,Test tube holder,Solid sample holder,Deuterium lamp,Halogen lamp,4-place Cell holder,Printer,Water-jacketedcell holder,Reflection accessory 5°,Auto 8-cell changer,Micro cell holder,Water-jacketed cell holder,Constant-temperature system | ||
Power Supply | AC110V/220±10% ,60/50Hz | ||
Packing Size(mm) | 620*500*370 | 620*500*370 | |
Gross Weight(kg) | 18 | 16.5 |