YT4
4000
0.5mL, 1.5mL, 2mL, 5mL, 7mL
2000xg
No
12x7ml
Availability: | |
---|---|
Quantity: | |
YT4 Serofuge,Cell Washer Centrifuge,4000rpm,12×7ml with SERO Rotor,HLA Rotor
Features:
1. Microprocessor control, less noisily, it is widely used to qualitative analysis of blood serum, plasma and urea in the fields of hospital, laboratory and biochemistry.
2. Brushless motor, free maintenance, no powder pollution, quick in speed up and down.
3. Special program, HLA and SERO separately.
4. Micro computer control system, LED display the RCF,time and speed.
5.Electric lid lock, compact design, super speed and imbalance protection.
YT4 Technical Parameter:
Max. Speed | 4000rpm |
Max. RCF | 2000 |
Max. Capacity | 12×7ml |
Time Range | 0~99min |
RPM/RCF Convert | Yes |
Noise (dB) | ≤ 55 |
Temperature | Normal |
Acc/Dec | 10 Kinds |
Speed Accuracy | ±20r/min |
Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
Size (W x D x Hmm) | 485×320×255mm |
Net Weight(kg) | 20kg |
Matched Rotors for YT4
Order No. | Rotor | Max Speed (rpm) | Max Volume (ml) | Max. RCF(×g) |
NO31501 | SERO Rotor | 3000 | 12×7/5ml(10-13*65-100mm) | 1000 |
NO31502 | HLA Rotor | 4000 | 12×2/1.5/0.5ml | 2000 |
Rotor Name | Max RCF(×g) | Use |
HLA rotor for Lymphocyte washing | 2000 | Lymphocyte separation incubated cell separation |
1000 | Hematoblast extenterate(thrombin disposal) | |
1000 | Lymphocyte washing | |
SERO rotor for erythrocyte washing | 500 | Blood type determination, the image of the hematocyte |
1000 | The test of intersectant aptness | |
1000 | Hematocyte washing, the distillation of the serum and plasma |
YT4 Serofuge,Cell Washer Centrifuge,4000rpm,12×7ml with SERO Rotor,HLA Rotor
Features:
1. Microprocessor control, less noisily, it is widely used to qualitative analysis of blood serum, plasma and urea in the fields of hospital, laboratory and biochemistry.
2. Brushless motor, free maintenance, no powder pollution, quick in speed up and down.
3. Special program, HLA and SERO separately.
4. Micro computer control system, LED display the RCF,time and speed.
5.Electric lid lock, compact design, super speed and imbalance protection.
YT4 Technical Parameter:
Max. Speed | 4000rpm |
Max. RCF | 2000 |
Max. Capacity | 12×7ml |
Time Range | 0~99min |
RPM/RCF Convert | Yes |
Noise (dB) | ≤ 55 |
Temperature | Normal |
Acc/Dec | 10 Kinds |
Speed Accuracy | ±20r/min |
Voltage(V/Hz) | AC 220V/110V 50HZ/60HZ |
Size (W x D x Hmm) | 485×320×255mm |
Net Weight(kg) | 20kg |
Matched Rotors for YT4
Order No. | Rotor | Max Speed (rpm) | Max Volume (ml) | Max. RCF(×g) |
NO31501 | SERO Rotor | 3000 | 12×7/5ml(10-13*65-100mm) | 1000 |
NO31502 | HLA Rotor | 4000 | 12×2/1.5/0.5ml | 2000 |
Rotor Name | Max RCF(×g) | Use |
HLA rotor for Lymphocyte washing | 2000 | Lymphocyte separation incubated cell separation |
1000 | Hematoblast extenterate(thrombin disposal) | |
1000 | Lymphocyte washing | |
SERO rotor for erythrocyte washing | 500 | Blood type determination, the image of the hematocyte |
1000 | The test of intersectant aptness | |
1000 | Hematocyte washing, the distillation of the serum and plasma |